Precautions of Laser Machine

precautions
  1. Make sure that the power socket is in good contact and the ground wire is reliably grounded.
  2. Please ensure that the working voltage of the chiller is stable and normal. Because the water cooler is more sensitive to the power supply voltage.
  3. Mismatched power frequency will cause damage to the machine.
  4. Please use 50Hz or 60Hz models according to actual conditions.
  5. To protect the circulating water pump, it is strictly prohibited to run without water. The water storage tank is emptied before the new laser cutting machine is packed. Please make sure that the water tank is filled with water before turning on the machine. Otherwise, the pump can easily break.
  6. Please ensure that the air inlet and outlet channels of the chiller are smooth. The air outlet on the chiller must be at least 1250px away from the obstacle. And the side air inlet must be at least 500px away from the obstacle.
  7. Clean the filter of the air inlet regularly. We must remove and wash the dust-proof net regularly. Because the serious blockage of the dust-proof net will cause the chiller to malfunction.
  8. Please pay attention to the influence of condensed water. When the water temperature is lower than the ambient temperature and the ambient humidity is high, the circulating water pipe will produce condensed water. When the above situation occurs, it is recommended to increase the water temperature or heat the water pipe and the cooled device.
  9. The laser cutter is a professional industrial cutting equipment, please do not let non-professionals operate it.

Leave a Reply

Your email address will not be published. Required fields are marked *

1 + 18 =